The Ruud RGFG 95% Two Stage Modulating Variable gas furnace features all stainless steel heat exchanger for maximum durability to rust and corrosion and is renowned for its dependability.This is one of the quietest 95% furnaces on the market with its super sound barrier front door.These furnaces are factory run tested for heating and combination heating and cooling applications.With a heavy steel gauge insulated steel cabinets with a high quality durable baked paint finish.

Features

  • One of the industries quietist 95% furnace on the market
  • All stainless steel heat exchanger
  • Modulating Function: When used with the modulating thermostat the heating rate is between 40% and 100% of capacity
  • Two Stage Function: When used with a two stage thermostat, furnace operates at 40% on first stage, amd stahes up to 65%, them 100% for second stage
  • Multistage Function: When used with a single stage thermostat, furnace functions as a three stage furnace operating at 40%, 65% and 100% total capacity
  • Variable ECM motor for even temperatures throughout house
  • ECM provides optimum humidity control
  • Ready to operate right out of box and can be converted to propane with optional propane kit
  • Super quiet designed door delvering one of the top quietest furnaces on the market
  • Single plate in-shot burners will never be out of alignment
  • ECM variable blower motor to deliver maximum airflow
  • Specially designed two speed draft inducer motor foe extra quiet operation
  • Left or right side gas connection and side or bottom return air inlet
  • All metal vent motor no plastic is used for less equipment failures
  • Integrated circuit board with self diagnostics for easy troubleshooting
  • Multiply safety controls such as roll outs,pressure switch to prove combustion and Hi-Limit safety control
  • Evaporator coil and furnace assembly fit for proper air flow through coil
  • Direct spark ignition system with patented adaptive learning system for maximum energy savings and longer ignition life
Product Specifications
High Fire Input BTU 75000 BTU
High Fire Output BTU 72000 BTU
Low Fire Input BTU 30000 BTU
Low Fire Output BTU 28500 BTU
Efficiency 95%
Stages Two Stage Variable Modulating
Blower Capacity 3 Ton - Variable ECM - 1200 CFM
Configuration Upflow
Breaker Size 15 Amps
Flue Vent Size 2 Inch PVC
Weight 153 lbs
Dimensions 17.5"W x 28"D x 34"H
Plenum Opening 16 11/32"W x 20"D
Heat Exchanger Warranty Lifetime with online registration
Parts Warranty 10 Years with online registration

Important Safety Notice

Do not try to install any furnace,space heater or central air conditiong equipment or their associated installation supplies or replacement parts unless you are qualified with the proper experience to work on said equipment.Air conditioning equipment comes pre-charged with refrigerant and by Federal Law cannot be discharged into the atmosphere. You can purchase the equipment and do not have to be EPA certified. If you are mechanically inclined you can perform all the work yourself, except we strongly recommend that you use a professional HVAC licensed contractor to do the final steps of the installation to properly set up the equipment and to make sure that the equipment is istalled properly and safely. A HVAC contractor will have the proper tools and equipment to perform the final steps.If you do not have the proper experience to install or repair furnaces, space heaters or central air conditioning systems of which you are purchasing from Heating and Cooling Air,LLC, you must contact a licensed HVAC contractor to perform the work for you. You will be required to be sure that the work performed is in accordance with local building, electrical and mechanical codes.All products installed by you or your contractor must be installed in accordance with the manufacturers installation and safety instructions. Unqualified installation of furnaces, space heaters and air conditioning equipment, installation supplies or parts can result in loss of warranty, damage to the equipment, property damage, personal injury od death. By purchasing from Heating and Cooling Air, LLC you agree to not hold responsible or liable in any way Heating and Cooling Air,LLC, its officers, the product manufacturers or any other distributor of your purchased items for any damages, liability or legal litigation for any damages, consequences or injury that result from improper installation or use of products.

 

Instructions & Brochures
Specifications
RGFG Furnace
Brochures
RGFG Furnace
Warranty
Ruud






Product Rating: (0.00)   # of Ratings: 0   (Only registered customers can rate)

There are no comments for this product.
Security Badges